Datasheet HS1101LF (TE Connectivity) - 3

制造商TE Connectivity
描述Relative Humidity Sensor
页数 / 页6 / 3 — BLOCK DIAGRAM. CIRCUIT. Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ …
文件格式/大小PDF / 219 Kb
文件语言英语

BLOCK DIAGRAM. CIRCUIT. Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF

BLOCK DIAGRAM CIRCUIT Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF

该数据表的模型线

文件文字版本

HS1101LF Relative Humidity Sensor MEASUREMENT FREQUENCY INFLUENCE In this data sheet, all capacitance measurements are done @ 10 kHz / 1Volt. However, the sensor can operate without restriction from 5 kHz to 300 kHz POLARISATION In order to get a better reproducibility during measurements, always connect the case of the header (pin 2) to the ground of the circuit. The case of the header is located on the opposite side of the tab. SOLDERING INSTRUCTIONS We recommend taking specific attention to soldering conditions to get the best performance of MEAS-France sensors. See Application Note. To get it, please contact: humidity.application@te.com. PROPORTIONAL VOLTAGE OUTPUT CIRCUIT
BLOCK DIAGRAM
FREQUENCY OUTPUT CIRCUIT
CIRCUIT Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF
SENSOR SOLUTIONS /// HS1101LF HPC052_J 9/2015 Page 3 Document Outline HS1101LF Relative Humidity Sensor