HMC-AUH312Data SheetTable 4. Recommended Operating Conditions Without Bias TeeParameterSymbolMinTypMaxUnit POSITIVE SUPPLY Voltage 6 8 8.25 V Current 60 65 mA GATE VOLTAGE Gate Voltage 1 VGG1 −1 +0.5 V Gate Voltage 2 VGG2 1 1.8 V POWER DISSIPATION VDD = 6 V 360 mW VDD = 8 V 480 mW RF INPUT POWER 4 dBm OPERATING TEMPERATURE −55 +25 +85 °C Rev. F | Page 4 of 5 Document Outline Features Applications Functional Block Diagram General Description Table of Contents Revision History Specifications 0.5 GHz to 60 GHz Frequency Range 60 GHz to 80 GHz Frequency Range Recommended Operating Conditions Absolute Maximum Ratings ESD Caution Pin Configuration and Function Descriptions Interface Schematics Typical Performance Characteristics Theory of Operation Applications Information Applications Overview Device Mounting Device Operation Device Power-Up Instructions Device Power-Down Instructions Mounting and Bonding Techniques for Millimeterwave GaAs MMICs Handling Guidelines for ESD Protection of GaAs MMICs Handling Precautions Opening the Protective Packaging Storage Cleanliness Static Sensitivity Transients General Handling Mounting Techniques Eutectic Die Attach Epoxy Die Attach Wire Bonding Outline Dimensions Ordering Guide