Datasheet SiC951 (Vishay) - 6

制造商Vishay
描述4.5 V to 20 V Input, 25 A MicroBRICK DC/DC Regulator Module With PMBus Interface
页数 / 页28 / 6 — SiC951. ELECTRICAL SPECIFICATIONS. LIMITS. PARAMETER TEST. CONDITIONS. …
文件格式/大小PDF / 3.1 Mb
文件语言英语

SiC951. ELECTRICAL SPECIFICATIONS. LIMITS. PARAMETER TEST. CONDITIONS. UNIT. MIN. TYP. MAX. Controller and Timing

SiC951 ELECTRICAL SPECIFICATIONS LIMITS PARAMETER TEST CONDITIONS UNIT MIN TYP MAX Controller and Timing

该数据表的模型线

文件文字版本

SiC951
www.vishay.com Vishay Siliconix
ELECTRICAL SPECIFICATIONS
(PVIN = 12 V, TJ = -40 °C to +125 °C, unless otherwise specified)
LIMITS PARAMETER TEST CONDITIONS UNIT MIN. TYP. MAX. Controller and Timing
Minimum on-time - 50 - ns tON accuracy -10 - 10 % Frequency accuracy Default frequency is 600 kHz 540 600 660 kHz Frequency setting range CCM mode 300 - 1500 Minimum off-time - 250 - ns
VOUT Soft Start / Soft Stop
tON_RISE From VOUT = 0 V to VOUT set point 0 - 127 tON_DELAY From ON_OFF_CONFIG invoked until VOUT set point 0 - 127 From the end of the turn-off ms tOFF_FALL delay time until the voltage is commanded to zero 0 - 127 IOUT_OC_FAULT_LIMIT current must not be exceeded tOFF_DELAY From ON_OFF_CONFIG invoked until VOUT = 0 V 0 - 127
VOUT Faults
Time to detect and set fault registers for OV warn, OV fault, (configurable) - 100 - ns VOUT faults (VOUT UV warning and fault has 78 Hz filtering time) Time to power up the output tON_MAX_FAULT_LIMIT 0 - 127 without reaching the output under voltage fault limit ms Time to power down the output tOFF_MAX_WARN_LIMIT 0 - 127 without reaching 12.5 % of VOUT set point
Power Good
VOUT rising (default value, can be changed by PMBus) - 90 - Power good output threshold VOUT falling (default value, can be changed by PMBus) - 85 - % Power good hysteresis Default rising and falling thresholds - 5 - Power good on resistance - 5.5 - Ω Power good delay time (rising) - 25 - μs Power good delay time (falling) - 30 -
Temperature Monitor and Temperature Shutdown
Resolution - 1 - Range -40 - 150 Accuracy - ± 5 - °C Thermal shutdown - 125 - Thermal shutdown hysteresis - 35 -
Digital Inputs ADDR, SALRT, SCLK, SDA, EN
VIH Input high threshold 2 - - VIL Input low threshold - - 0.8 V VHYST Input hysteresis - 0.1 - CPIN Input C - 5 - pF S23-0736-Rev. C, 12-Sep-2023
6
Document Number: 71554 For technical questions, contact: powerictechsupport@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000